APPLICATIONS
The Kingspan TEK Building System consists of structural insulated
roof and wall panels, which can be used to create buildings with
a maximum of of 4 storeys. Because of their light weight of as little as 19kg/mē they are ideal for use, where heavy constructions are not possible.
STRUCTURAL INSULATED PANEL DIMENSIONS
Width: 200 mm (min) - 1245 mm (max) Length: 7450 mm (max) - for walls a maximum 3m storey height is allowed.
RECOMMENDED CONSTRUCTIONS
Internal/partition walls:
- basic panel or timber stud with 12.5 mm plasterboard both sides.
External walls:
- basic panel lined with 12.5 mm plasterboard inside and clad
externally with an insulated render system with independent accreditation
for use on the TEK Building System e.g. Permarock Kooltherm
System;
- basic panel lined with 12.5 mm vapour check plasterboard inside
and externally brick-clad with a minimum 50 mm cavity between
a breather membrane (attached to the outside of the panel) and
the brick leaf; or
- basic panel lined with 12.5 mm plasterboard inside and clad
externally with a breather membrane and timber boarding on 25
x 50 mm vertical tanalised timber battens.
Roofs:
- basic panel lined with 12.5 mm vapour check plasterboard inside
and covered with a vapour permeable membrane, counter battens,
tiling battens and slates/tiles externally.
Long lasting external weather proofing is a necessary part of the
Kingspan TEK Building System.
The Kingspan TEK Building System is not recommended for cellars
or basement constructions.
THERMAL PERFORMANCE
The thermal conductivity of the OSB 3 is 0.13 W/mK. That of the rigid urethane insulation core is 0.023 W/mK.
WATER VAPOUR RESISTIVITY
Vapour resistivity of Kingspan TEK Structural Insulated Panel components:
- the rigid urethane core- 300 MNs/gm;
- the OSB 3 facing - 500 MNs/gm.
RESISTANCE TO SOLVENTS, FUNGI & RODENTS
The insulation core is resistant to dilute acids, alkalis, mineral
oil and petrol. It is not resistant to some solvent-based adhesive
systems, particularly those containing methyl ethyl ketone. Adhesives
containing such solvents should not be used in association with
Kingspan TEK Building System. Kingspan TEK Building System
components which have been in contact with harsh solvents, petrol,
mineral oil or acids, or components that have been damaged in any
way should not be used.
The Insulation core and facings used in the manufacture of Kingspan
TEK Structural Insulated Panels resist attack by mould and microbial
growth and do not provide any food value to vermin.
FIRE PERFORMANCE
When lined internally with 12.5 mm plasterboard the Kingspan TEK
Building System will achieve Class O to the Building Regulations.
|